NS-EN ISO-9001:2008 / ISO-9001:2008

FAQ,s

1. What is ultrasonic and how does it work?
Ultrasound is energy in the form of a wave motion which is above the maximum level of audible sound. This energy is transmitted to the cleaning solution via a bank of transducers underneath the machine. Cleaning takes place as shock waves dislodge soil from the surface of the contaminated articles placed in the water bath.

2. Why do I need to degas the fluid prior to the cleaning process?
After filling the tank with water (not temperature critical) and adding a measured amount of recommended detergent, then switch on your machine for a few minutes in order to expel dissolved air bubbles as these bubbles will affect the cleaning effectiveness. You will notice a change in sound and hear a high pitch "hissing" sound when degassing process is completed. When loading each time, place the basket/tray inside the tank gently to avoid re-introducing air into the fluid. Degassing time will vary depending on type of chemical used (e.g. aqueous or solvent), temperature, viscosity etc.

3. How long do I need to clean the surgical instruments?
It should take 3-5 minutes. Extended times are likely to re-deposit the soil removed back onto the instruments. Generally, it is difficult to establish guidelines due to the several factors need to be considered as follows:

1. Wide variety of sizes, weights etc.
2. Using appropriate cleaning solution.
3. Overload the machine with unnecessary mass.


It is therefore wiser to start with a few parts so that they can be cleaned quickly and thoroughly.

4.How often do I need to change water?
When the water is heavily contaminated, it should be immediately replaced. Replacement of the cleaning solution is necessary at least daily (where the machine is used daily) or more frequently, depending on how many what types of parts are being cleaned in your ultrasonic cleaner.

5. How do I clean my ultrasonic cleaner?
Clean the tank regularly. Use an appropriate suitable stainless steel cleaning powder if the tank is stained with marks. If the outer sealing compound is marked, wipe over with general purpose cleaner, else use the finest available sandpaper and carefully polish out the scratch.

6. Can ultrasonic cleaning damage my parts?
With certain cautions, ultrasonic cleaning is considered safe for most parts. The cleaning process is safe since the energy is localized at the microscopic level. The most important cautionary consideration is the choice of cleaning solution. Ultrasonic cleaning is not recommended for the following gemstones: opal, pearl, emerald, tanzanite, malachite, turquoise, lapis and coral.

7. What cleaning solution should I use?
Modern ultrasonic cleaning solutions are compounded from a variety of detergents, wetting agents and other reactive components. A large variety of excellent formulations are available, designed for specific applications. Proper selection is crucial for acceptable cleaning activity and to preclude undesirable reactivity with the part being cleaned. Thoroughclean can help you to identify either the optimal 'stock' cleaning formula, or likely candidates to test and evaluate.

8. Why must I keep solution at the tank's level indicator?
The solution level should always be maintained at the level indicator in the tank, with trays or beakers installed. The ultrasonic cleaning system is a 'tuned' system. Improper solution levels will change the characteristics of the environment, can affect the system frequency, decrease effectiveness, and potentially damage the transducers.

9. Why must trays or beakers be used?
Items being cleaned should never be placed directly on the tank bottom. Transducers (which produce the ultrasound) are bonded to the bottom/side of the tank. Items resting directly on the tank bottom can damage the transducers and/or reduce cavitations. Additionally, a tray or beaker will position the item within the optimal cleaning zone of the tank, and will hold the load together and allow for easy, no-touch removal, draining and transport of the items to the next step.

10. What is the optimum cleaning temperature?
Heat usually enhances and speeds up the cleaning process, and most detergent solutions are designed to work best at an elevated temperature. Usually, the best results are within the 50°C - 60°C range.

11. What is the warranty?
Our cleaner is guaranteed for a period of one (1) year from date of purchase. Extended warranty period up to two (2) years also available. Conditions apply.



Quality Policy

“We at Thoroughclean Ultrasonic India Pvt.Ltd. are committed to provide manufacturing & marketing of the product as per customer's requirement in time, through continual improvement in quality management systems and invovement of its employees.“

We Offer

  • Standard / Custom - Built Multi Tank Cleaning & Drying System in S.S. AISI 316L grade.
  • Conveyorised multi tank cleaning system.
  • Electroplating & Electrophoretic Equipments.
  • Portable / mobile precious metal brush / Pen plating equipment.

Quick Contact

First Name
E-mail ID
Mobile
Query

Address

Regd. Office :
305-307, VARDHMAN CITY CENTRE - 1
Shakti Nagar - Gulabi Bagh Crossing
Near Shakti Nagar Railway Underbridge,
New Delhi 110052
Phones: 2365 4117 / 2365 4118 / 2365 4119
Fax: 91-11-2365 3488
Email : enquiry@thoroughclean.com

Copyright © Thoroughclean Ultrasonic (India) Pvt. Ltd. Website, All Rights Reserved

Site Developed by www.mindsandmarket.com